Ocean Insight Spectrometers & Accessories
Ocean HDX
Absorption / Reflection / Transmission/PL
High sensitivity
Back-thinned CCD image sensor,
High resolution,2048sensors, 200-1100nm
Res. 1nm, Replaceable Slits, 6ms to 10s
On board memory 5000 spectra
Signal to nms 400:1
Stray light >3AU, Dynamic Range 1200
Ocean FX
Range :200-850nm, 350-1100nm, 200-1025nm
Resolution -1.3/2nm,
Integration for 10µs to 10s,
High-sensitivity CMOS detector,
On board memory 50,000 spectra, 4500scans/s
SN ratio 290:1
USB/Ethernet
QE Pro
Absorption / Reflection /PL/ Transmission/Raman
High sensitivity, 22e-/count
TE cooled to -25 0 C, 200-1100nm
1024 x 58 Pixels, Bach thinned
Dynamic range 85000:1
On board memory 15000spectra
signal-to-noise ratio >1000:1
Ocean SR
competitively price
Wavelength 200-1100nm
Range 200-850nm, 350-1000nm, 220-1025nm
Integration time: 1µs to 2s, USB type C
Small optical bunch 88x63x318nm
Replaceable slit, 3648 sensors, 8x 200um
Ocean HR
220-1100nm, resolution: /nm
8x200um/3648 OR 14nm x200nm
14s -2 s measurement time
Large optical bench 148x106x182nm
Ocean ST
Spectrometer – Absorbance
Menatation OEM, Low resolution, Volume Pricing choose
400nm in 200-1100nm
NIR Quest
900-1700nm, 900-2100nm, 900-2500nm
Detectors 256 or 512
Resolution 5-10nm
TE coolded
Light Sources
DH2000BAL
Absorption / Reflection / Transmission
Wavelength Range: 210nm – 2.5μm
Source: Deuterium & Tungsten Halogen
HL 2000 HP FHSA
Reflection / Absorption / Transmission
360-2000nm,20Watts, Shutte,r Attanuator
DH3P CAL
Radiometrically Calibrated Light Source
Wavelength Range: 210nm – 1.1μm
Source: Deuterium & Tungsten Halogen
HG-2
Wavelength calibration 253-900nm
Product: Spectrometer HG-2 Mercury-Argon Wavelength
Calibration Sources
LASERS/LEDS
300W Xe Lamp PL
300W Lamp/ Power display
200-850nm
Monochrometer
SAMPLE COMPARTMENT
SQUARE ONE
10mm path Absorption/PL
Product: SQUARE ONE Cuvette Holder
Collimating Lenses: Three 74-UV fused silica lenses (200-
2000 nm)
Filter Slot Specification: Two slots in total. Each slot accepts
CUV UV
10mm path Product: CUV-UV Cuvette Holders
Collimating Lenses: Two 74-UV f/2 fused silica lenses (200-2000 nm)
Filter Slot Specification: Accepts filters up to 6.35 mm (1/4”) thickness
Integrated Light Source: No
Pathlength: 1 cm
CUV-UV Cuvette Holder
CUV FL DA
10mm path
90%/PL
Product: CUV-FL-DA
Collimating Lenses: One of 74-UV fused silica lens (200-2000
nm)
Filter Slot Specification: Accepts filters up to 6.35 mm (1/4”)
thickness
RTL STAGE
Product: STAGE-RTL-T Reflection-Transmission Stage
Base Dimensions: 206.3 mm diameter
Rail Height: Adjustable to 400 mm
Sample Area Dimensions: 152.4 mm diameter
STAGE-RTL-T Reflection-Transmission Stage
FIA-Z-SMA-ULT
10mm path
Cell Material: Ultem
Internal Volume: 26 µL
Pathlength: 10 mm
Wavelength Range: 210nm – 2μm
Window Material: Fused silica
FIA-Z-SMA-ULT
Fibbers
R400-7-UV VIS
Product: R200-7-UV-VIS
Wavelength Range: 300nm – 1.1μm
Fiber Core Size: 200 µm
Length: 2 m
Jacket: PVDF zip tube
Probe Ferrule Diameter: 6.35 mm (1/4″)
Solarization Resistant Reflection/Backscatter Probe
TP300-2-UV VIS
Product: TP300-UV-VIS
Wavelength Range: 200nm – 1.1μm
Fiber Core Size: 300 µm
Length: 2 m
Jacket: PVDF zip tube
Probe Ferrule Diameter: Internal stainless steel probe assembly: 3.175 mm (1/8″) and
PEEK polymer sleeve: 6.35 mm (1/4″)
Harsh Environment Transmission Dip Probe
QBIF 200 MIXED
Product: QBIF200-MIXED
Wavelength Range: 300nm – 2.1μm
Fiber Core Size: 200 µm
Length: 2 m
Jacket: Silicone-coated steel monocoil
Mixed UV-Visible & Visible-NIR Bifurcated Fibers
QP-400-2-UV VIS
Product: QP400-2-UV-VIS
Wavelength Range: 300nm – 1.1μm
Fiber Core Size: 400 µm
Length: 2 m
Jacket: Silicone-coated steel monocoil
UV-Visible Fiber