All Products

Setaram

Productline

Setline Family

TGA 11000C

DSC -170 to700C

TGA/DSC   1100C/400C

Themys Family

TGA  1600C

DSC 1600C

TGA/DSC  1600C

Calorimetric Family

-196 to 200C

-120 to 200C

RT to1600C

RT-600C

Setline Family

Setline TGA

RT -1100C

Heat Rate 0.01 to 500C/min

Tem Accuracy ± 10C

Mass Variation ± 20 or± 200mg

Mass resolution : 0.0023ug

Weight Accuracy –  0.03%

Auto sampler (optional)

Setline DSC

-170 to 700C

0.01 to 100C heating rate

Enthalpy accuracy+/- 0.8 

Temperature accuracy : 0.3C

DSC range +/- 6000mW

Gases 2

Autosampler (optional)

Setline STA

TGA+DSC

RT -1100C

  1. to 50C heating rate

Mass range 200 mg / 1000 mg

Mass resolution 0.05 /0.5 μg

DSC resolution 2.5 μW

Detailed Description

Thermal Analysis has applications in many academic and industrial fields including but not limited to Material Science, Metallurgy, Polymer and Physical Chemistry, Energy, Chemical Engineering, Geoscience, Pharmacy and Food Science. This diversity highlights the variety of institutes and companies who use thermal analysis instruments and often on a continual basis.

With educational and quality-control needs in mind, Setline® thermal analysis instruments are designed for simplicity and power.

Setline® is easy to use and easy to own

EASY TO USE

  • Setline® is easy to use accross diverse academic fields
  • Setline’s® compact design is robust and space efficient
  • Options focussed around core needs ensure ease of use and quicker mastery
  • Setline’s® robots (DSC+ and STA+) automate sample handling across multiple experiments

EASY TO OWN

  • Setline® is built for durability in high use situations
  • Cost of ownership is lowered through simplified maintenance for minimum down time and a Replacement Parts Guarantee*
  • Setlines® Technical and Application support ensures fast, expert help on any question

SETLINE FAMILY

Our range of instruments for the characterization of materials across wide temperature ranges and using all common thermal analysis techniques.

CALISTO – THERMAL ANALYSIS SOFTWARE

                CALISTO 2.0 is the industry standard thermal analysis software developed for all Setaram                            instrumentation and applications. It’s quick to install and comprises of two independent parts:

  • CALISTO ACQUISITION: dedicated to the control and data acquisition of our thermal analysis systems.
  • CALISTO PROCESSING: for the treatment of Thermal Analysis Data independent of instrument type.

Applications:

Energy and Environment, Life sciences, Organic and Inorganic Material Science, Process Safety.

THEMYS FAMILY

Themys One

RT to 1150/RT to1600C

0.01 to 100 Heating rate

Gases -3

Balance : 1000mg /0.1µg or                              200mg/0.02ug

DSC 0.4µW

Auto sampler (optional)

Themys H2

TGA – RT to 1750C

DSC –RT to1000C

0.01 to 100C Heating rate

Volume  55-2500 µl /80-100 µl

Calorimetry resolution DSC -1 µw

Mass resolution 20mg/0.002mg, 200mg/0.02mg

Themys

TGA / TGA+DTA & TGA –DSC

RT 0.01 to 1000C heating rate

Volume 55-2500µl / 30 -300 µl/80-100 µl

Gas Option 3

Mass resolution 5mg/0.0005 µg, 200mg/0.023 µg,300mg/0.3 µg

TMA

RT to 1750C

0.01 to 100C Heating rate

3 gases

Range ± 2mm

Resolution : 0.2nm

Precision   ± 0.080C

Detailed Description

Owing to their symmetrical beam balances, the THEMYS line of thermal analysers combine the highest sensitivity, stability, and the most accurate measurements of mass variations vs temperature or time.

 

Most systems within the THEMYS family line provide the user with a high level of versatility thanks to a modular design. It may include the simultaneous measurement of heat flow

and mass variations with the STA versions of the instruments, or the identification of evolved gases by coupling the instruments with gas analysers, or the measurement of dimensional changes with a TMA module.

 

While horizontal thermo balances lead to perturbations of the mass variations and temperature signals when the sample transforms, the vertical design benefits from good stability.

When combined with the hang-down principle, the sample can be hung to the balance using very thin suspensions. They minimize the drift of the mass variation signal with temperature, which is also known as buoyancy effect. Finally, the dual furnace version of hang-down balances are designed to directly subtract this drift from the mass variation signal and reach the best stability and thus the highest measurement accuracy possible.

 

Our range of instruments for the characterization of materials across wide temperature ranges and using all common thermal analysis techniques.



CALISTO – THERMAL ANALYSIS SOFTWARE

                CALISTO 2.0 is the industry standard thermal analysis software developed for all Setaram                            instrumentation and applications. It’s quick to install and comprises of two independent parts:

  • CALISTO ACQUISITION: dedicated to the control and data acquisition of our thermal analysis systems.
  • CALISTO PROCESSING: for the treatment of Thermal Analysis Data independent of instrument type.

Applications: Energy and Environment, Life sciences, Organic and Inorganic Material Science, Process Safety.

DSC, 3D Cp, TGA, STA, EGA, TMA, Humidity and corrosive studies

 

Calorimeter- Calvet Family



Calvet Cryo

-196 to 2000C

Temperature accuracy  0.5C

Enthalpy 0.2%,

Precision 0.5%

12.5ml volume

Calvet Pro

-120 to 200C/ RT  to 830C

Temp Accuracy 0.05C

Enthalpy ± 0.8%

Calorimetry ± 0.4%,

Volume 0.32ml

Calvet HT

RT  to 600C 

Accuracy  ± 1C

Enthalpy ± 1%

Calorimetry ±1.5%

Volume 7ml

Calvet DC

RT to 1500C/RT to 1300C, RT to1600C

Temp. Accuracy ± 2C

Calorimetric +2%

Resolution 5µm

Volume 5m

 Detailed Description

MICROCALVET CALORIMETRY FAMILY

 

Owing to their 3D sensors and Joule effect calibration, the MICROCALVET line of micro calorimeters combine the highest sensitivity and the most accurate measurements of temperature and of:

  • Heat: for the characterization of any heat releasing or heat absorbing phenomenon
  • Specific Heat Capacity (CP) : for any application requiring this key thermo physical property, like heat transfer calculation or heat management



The micro calorimeters of the MICROCALVET line use the latest evolution of the 3D sensor design in which a sample and reference cells are surrounded by semiconductor-based Peltier elements allowing for the measurement of all heat including radiation, convection or conduction. The 3D sensor is up to 95% efficient whereas typical plate DSC sensors are between 30-50%.

 

MICROCALVET line sensors use a specific electrical calibration also called Joule effect. It can be performed at any constant temperature, or under scanning conditions, and does not require reference materials.

 

The combination of 3D sensor efficiency and absolute Joule effect calibration provides an unparalleled accuracy of measurement independent of sample nature or matrix – solid, liquid, gas, powder etc.



MICROCALVET LINE CALORIMETERS


Our range of micro calorimeters for the characterization of materials across wide temperature ranges and using all common calorimetry techniques.

MICROCALVET

-45oC TO 120oC

DSC, 3D Cp, Humidity,Pressure Vacuum, Mixing, Corrosive and Reactive Studies, Coupling

MICROCALVET ULTRA

-20oC TO 170oC

DSC, 3D Cp, PressureVacuum, Mixing, Corrosive and Reactive Studies, Coupling

MICROCALVELT ULTRA 4C

-20oC TO 170oC

2D, 3D Cp, Pressure Vacuum, Mixing, Corrosive and Reactive Studies, Coupling

CALISTO – THERMAL ANALYSIS SOFTWARE

  CALISTO 2.0 is the industry standard thermal analysis software developed for all Setaram  instrumentation and applications. It’s quick to install and comprises of two independent parts:

  • CALISTO ACQUISITION: dedicated to the control and data acquisition of our thermal analysis systems.
  • CALISTO PROCESSING: for the treatment of Thermal Analysis Data independent of instrument type.

Applications: Energy and Environment, Life sciences, Organic and Inorganic Material Science, Process Safety.

 For further information https://setaramsolutions.com/

Menu

Contact Us

Contact Services

Contact Sales

Choose Your Nearest Branch & Contact Now

Mumbai Office

G-8/G-4,New Brahmand Annex
Phase- 8,Azad Nagar, Dharmachapada,
Near Ghodbunder Road,
Thane (W) - 400 607, Mumbai

 

Bangalore

No. 31, Opp: S.J.E.S. College
Old Madras Road,
Medahalli, Virgonagar,
Bangalore 560 049       

Mobile: 093412 82569

Email: bangalore@sinsil.in

Kolkata

A/88, Survey Park,
Near Mother Dairy,
Santoshpur
KOLKATA (W.B.) – 700 075

Mobile : 09681442892
Email : kolkata@sinsil.in

Delhi

409D,4TH Floor, SRS Tower,
14/5, Mathura Road
(Near Mewla Mahrajpur Metro Station)
FARIDABAD  Pin- 121003

Mobile : 09312437300
Email : delhi@sinsil.in

Varodara

No. 165, Parishram Park,
Gorwa, Baroda -390 016

Hyderabad

Secunderabad / Hyderabad

Mobile:080089 99507

 

Chennai

T. Nagar, Chennai

Mobile : 09341282569/093412 82569
Email:bangalore@sinsil.in / chennai@sinsil.in